Testing Lock Functionality
Pass a Construction key over the Quantum RFID LPI probe. Be sure that the green light flashes for five
seconds while the exterior lever remains operable. If the green light does not flash, refer to the table
below.
Lock Communication Electronic Function Description
Red and green LEDs flash Time and date not set, use the Quantum RFID LPI probe to reset
nine times simultaneously
Yellow LED flashes 12 times Dead bolt is thrown or switch cam is not properly aligned
Yellow LED flashes two times Keycard not allowed OR keycard cancelled by new keycard
Red and green LEDs flash Low battery (contact the SAFLOK service department)
alternately nine times
Yellow and red LEDs flash Bad keycard read or corrupted data (may require new
two times simultaneously keycard)
Red LED flashes two times Keycard not read (keycard inserted upside-down, wrong end,
wrong key?)
SAFLOK Door Unit Inspection Criteria
Appearance
Finish is free of blemishes or scratches that would distract from lock appearance
Lock body and under plate (if used) are mounted straight on the door
Door scalp is mounted straight and flush with the door edge
Jamb strike is mounted straight and is flush with the jamb face
Correction of minor blemishes on the door jamb are the responsibility of the property’s maintenance
department
Lock Function
Knob or lever rotates and moves freely
Lever is horizontal to floor when at rest position
Dead bolt extends fully and retracts without binding (door open)
Lock latch and dead bolt engage jamb strike plate freely
Anti-pick latch when depressed (door open)
Anti-pick latch is depressed when contact is made with the strike plate (door closed)