User Manual Part 1

23
Merlin Protocol Analyzer User’s ManualCATC Version 1.6
monitoring, and event counting and sequencing. Both the BusEngine
program and the Firmware that manages the internal microcontroller are
fully field upgradeable.
Within a new software release, it may be necessary to update the Analyzers
BusEngine hardware for proper operation. The Readme file lets you know
if this is necessary.
To update the BusEngine,
Step 1 Click Update BusEngine on the Analyzer Setup screen.
You see the Select engine file window:
The program has already automatically searched for the correct file and
displays it in the File name field.
Note The most current Primary BusEngine file (Merlin.rbf) was copied to your
\CATC\Merlin directory when you installed the program.
Step 2 Click Open.
It is not necessary to restart the Analyzer. Once upgraded, the Analyzer
takes approximately 15 seconds to reinitialize, with Time Remaining
displayed on the screen. During this time the Trigger LED is on, indicating
that power-on diagnostics are being run. If there is a hardware failure, the
Trigger LED continues to blink after initialization is complete. If this
occurs, contact CATC for customer support.