Merlin Protocol Analyzer User’s ManualCATC Version 1.6
• Recording memory of 128MB - enough to record twenty five minutes of
high volume traffic.
Display Options
• Analyzes and displays a transaction-level view of piconet traffic with
accurate time-stamps and frequency hop information.
• Software analysis and data presentation at several protocol levels:
(Baseband, LMP, L2CAP, SDP, RFCOMM, TCS, OBEX, HDLC,
BNEP, PPP, and AT Commands).
Recording Options
• Flexible advanced triggering capabilities including - multiple triggering
modes, selective views, timing analysis, search functions, protocol
packet errors, transaction errors, packet type and destination device, data
patterns, or any of these trigger types in combination.
• User defined trigger position.
• Real-time hardware filtering of captured traffic for optimizing analyzer
memory usage.
Traffic Generation
• Traffic generation capability (when used in future add-on product).
Bluetooth™ BusEngine
CATC’s BusEngine™ Technology is at the heart of the new Merlin
Analyzer. The revolutionary BusEngine core uses state-of-the-art EPLD
technology and incorporates both the real-time recording engine and the
configureable building blocks that implement data/state/error detection,
triggering, capture filtering, external signal monitoring and event counting
& sequencing. And like the flash-memory-based firmware that controls its
operation, all BusEngine logic is fully field upgradeable, using
configuration files that can be downloaded from the CATC Website.