User Manual

106
CATC MERLIN’S WAND 1.22 APPENDIX A
User’s Manual Command Generator Command Descriptions
Read_Scan_Enable
Read_Scan_Enable will read the value for the Scan_Enable configuration
parameter, which controls whether or not Merlin’s Wand will periodically
scan for page attempts and/or inquiry requests from other Bluetooth devices.
Read_SCO_Flow_Control_Enable
The Read_SCO_Flow_Control_Enable command provides the ability to
read the SCO_Flow_Control_Enable setting. By using this setting, Merlin
can decide if the Merlin’s Wand Host Controller will send Number Of
Completed Packets events for SCO HCI_Handles.
Read_Stored_Link_Key
Read_Stored_Link_Key will read one or all link keys stored in the Merlin’s
Wand Host Controller.
Command Parameters Examples Comments
N/A
Return Events
Read_Scan_Enable_Complete
Read_Scan_Enable_Error
Command Parameters Examples Comments
N/A
Return Events
Read_SCO_Flow_Control_Enable_Complete
Read_SCO_Flow_Control_Enable_Error
Command Parameters Examples Comments
BD_ADDR 0x010203040506
Read_All_Flag 01 00=Return Link Key for
specified BD_ADDR
01=Return all stored Link
Keys
Return Events
Read_Stored_Link_Key_Complete
Read_Stored_Link_Key_Error