User Manual

92
CATC MERLIN’S WAND 1.22 APPENDIX A
User’s Manual Command Generator Command Descriptions
Authentication_Requested
Used to initiate authentication between the two devices associated with the
specified HCI_Handle.
Change_Connection_Link_Key
Used to force both connected devices to generate a new link key.
Change_Connection_Packet_Type
Used to change which packet types can be used for a connection that is
currently established.
Command Parameters Examples Comments
HCI_Handle 0x0001
Return Events
Authentication_Error
Authentication_Complete
Command Parameters Examples Comments
HCI_Handle 0x0001 Range: 0x0000-0x0EFF
Return Events
Change_Connection_Link_Key_Error
Change_Connection_Link_Key_Complete
Command Parameters Examples Comments
HCI_Handle 0x0001
Packet_Type 0x0008 Range: 0x0000-0x0EFF
0x0008 = DM1
0x0010 = DH1
0x0400 = DM3
0x0800 = DH3
0x4000 = DM5
0x8000 = DH5
Return Events
Change_Connection_Packet_Type_Error
Change_Connection_Packet_Type_Complete