User Manual
Table Of Contents
- Appendix B: Command Generator Examples
- B.1 Device Discovery and Remote Name Request
- B.2 Establish Baseband Connection
- B.3 Baseband Disconnection
- B.4 Create Audio Connection
- B.5 L2CAP Connection
- B.6 L2CAP Channel Disconnect
- B.7 SDP Profile Service Search
- B.8 SDP Reset Database and Add Profile Service Record
- B.9 RFCOMM Client Channel Establishment
- B.10 RFCOMM Client Channel Disconnection
- B.11 RFCOMM Register Server Channel
- B.12 Establish TCS Connection
- B.13 OBEX Server Init
- B.14 OBEX Client Connection and Client Get & Put
- Appendix C: Merlin’s Wand Scripting Commands
- C.1 Bluetooth Addresses
- C.2 Basic Commands
- C.3 Pipe Commands
- C.4 HCI Commands
- HCIAcceptConnectionRequest()
- HCIAddSCOConnection()
- HCIAuthenticationRequested()
- HCICatcBerTest()
- HCICatcChangeHeadsetGain()
- HCICatcEnterTestMode()
- HCICatcReadHeadsetGain()
- HCICatcReadRevisionInformation()
- HCICatcSelfTest()
- HCICatcTestControl()
- HCICatcWriteCountryCode()
- HCIChangeConnectionLinkKey()
- HCIChangeConnectionPacketType()
- HCIChangeLocalName()
- HCIDeleteStoredLinkKey()
- HCIEnableDeviceUnderTestMode()
- HCIExitParkMode()
- HCIExitSniffMode()
- HCIHoldMode()
- HCIMasterLinkKey()
- HCIParkMode()
- HCIPINCodeRequestNegativeReply()
- HCIPINCodeRequestReply()
- HCIQoSSetup()
- HCIReadAuthenticationEnable()
- HCIReadBDADDR()
- HCIReadBufferSize()
- HCIReadClockOffset()
- HCIReadConnectionAcceptTimeout()
- HCIReadCountryCode()
- HCIReadCurrentIACLAP()
- HCIReadEncryptionMode()
- HCIReadLinkPolicySettings()
- HCIReadLinkSupervisionTimeout()
- HCIReadLocalName()
- HCIReadLocalSupportedFeatures()
- HCIReadLocalVersionInformation()
- HCIReadLoopbackMode()
- HCIReadNumberOfSupportedIAC()
- HCIReadPageScanMode()
- HCIReadPageScanPeriodMode()
- HCIReadPageTimeout()
- HCIReadPINType()
- HCIReadRemoteSupportedFeatures()
- HCIReadRemoteVersionInformation()
- HCIReadScanEnable()
- HCIReadSCOFlowControlEnable()
- HCIReadStoredLinkKey()
- HCIReadVoiceSetting()
- HCIRejectConnectionRequest()
- HCIRemoveSCOConnection()
- HCIReset()
- HCIRoleDiscovery()
- HCISetConnectionEncryption()
- HCISetEventFilter()
- HCISniffMode()
- HCISwitchRole()
- HCIWriteAuthenticationEnable()
- HCIWriteConnectionAcceptTimeout()
- HCIWriteCurrentIACLAP()
- HCIWriteEncryptionMode()
- HCIWriteLinkPolicySettings()
- HCIWriteLinkSupervisionTimeout()
- HCIWriteLoopbackMode()
- HCIWritePageTimeout()
- HCIWritePINType()
- HCIWriteScanEnable()
- HCIWriteStoredLinkKey()
- HCIWriteVoiceSettings()
- C.5 OBEX Commands
- C.6 RFCOMM Commands
- RFCloseClientChannel()
- RFOpenClientChannel()
- RFRegisterServerChannel()
- RFSendData()
- RFSendDataFromPipe()
- RFReceiveData()
- RFWaitForConnection()
- RFAcceptChannel()
- RFAcceptPortSettings()
- RFCreditFlowEnabled()
- RFRequestPortSettings()
- RFRequestPortStatus()
- RFSetLineStatus()
- RFSetModemStatus()
- RFSendTest()
- RFAdvanceCredit()
- C.7 TCS Commands
- C.8 L2CAP Commands
- C.9 SDP Commands
- C.10 Merlin Commands
- Appendix D: CATC Scripting Language
274
CATC MERLIN’S WAND 1.22 APPENDIX D
User’s Manual CATC Scripting Language
y = 3;
}
x + 3;
}
Compound statements can be used anywhere that any other kind of
statement can be used.
if (3 && 3)
{
result = "True!";
Trace(result);
}
Compound statements are required for function declarations and are
commonly used in if, if-else, while, and for statements.
D.10 Preprocessing
The preprocessing command %include can be used to insert the contents
of a file into a script. It has the effect of copying and pasting the file into the
code. Using %include allows the user to create modular script files that
can then be incorporated into a script. This way, commands can easily be
located and reused.
The syntax for %include is this:
%include “includefile.inc”
The quotation marks around the filename are required, and by convention,
the included file has a .inc extension.
The filenames given in the include directive are always treated as being
relative to the current file being parsed. So, if a file is referenced via the
preprocessing command in a .script file, and no path information is provided
(%include “file.inc”), the application will try to load the file from
the current directory. Files that are in a directory one level up from the
current file can be referenced using “..\file.inc”, and likewise, files
one level down can be referenced using the relative pathname
(“directory\file.inc”). Last but not least, files can also be referred
to using a full pathname, such as
“C:\global_scripts\include\file.inc”.