User Manual

6-39
Quick Spec
Note
Remember, when shaft movement due to causes other than
misalignment is present in the data this will appear as a ran-
domness (noise) in the data. This is not normally a problem
when the misalignment great, but will increasingly interfere as
the misalignment decreases. Therefore, the better the align-
ment the more likely the chance of seeing the Unfit data
warning.
If you do encounter a machine where this becomes a problem too great to
overcome, consider switching to an alternative method such as Manual
Sweep or 4 Point Auto.
After viewing the dual tolerance plot, press Enter to store the reading and
continue. You now have a choice to either take more data using Quick
Spec, save this data, or align the machine. Either use any Number key on
the keypad to toggle between these choices, and then press Enter to accept
the choice; or press the Page Up key to review the results (dual tolerance
plot).
27
Selecting “Take More Data” will clear the previous readings and return you
to the start of the Quick Spec routine.