After the job has been defined and any soft foot condition corrected (if nec-
essary), select Alignment Data to acquire a new set of shaft readings.
7
The current laser readings are shown in reverse video just below the screen
title line. The current laser head position is shown graphically by a heavy
black line on the circles and numerically by the degree readings at the
bottom of the screen.
When the head positions and data are as desired press any number key on
the keypad to record data at the given point. The number of samples,
shown at the center of the screen, will increment by one (36 max).
8
Each time a data point is recorded and the heads are rotated to a new posi-
tion, a thinner line is left behind to denote where data was acquired.