User Manual
6-8 Acquiring Alignment Data
The current alignment method is always shown at the bottom center of the
main menu. Once the job has been defined and any soft foot has been cor-
rected (if necessary), prepare to measure the misalignment by selecting
Alignment Data from the Main Menu.
1
With Alignment Data highlighted, press the Enter key to start the data
acquisition procedure. The following screen will be displayed.
2
The next screen directs you to turn on the laser heads, position them at any
angular position you desire to start from, and then press the enter key to
initialize the laser heads. It is not required to define a sweep arc range and
direction of rotation due to the increased number of data readings acquired
every 2 degrees and the process, which automatically defines the direction
of rotation. Once the laser heads are initialized, the next screen appears
prompting you to now acquire the data by rotating the laser heads. After
the laser heads have been rotated, press the Enter key transmit or transfer
the data from the laser heads to the analyzer.