5-40 Using UltraSpec Alignment - General Overview
Storing Data Sets
From View Data the alignment readings and machine moves will be auto-
matically recorded and stored when the Enter key is pressed to exit from
either the dual tolerance plot or the Horizontal Log screen if viewing addi-
tional data details. This step returns you to the program’s Main menu.
When the readings and moves are recorded, a screen listing the number of
readings recorded for the current alignment job will appear for a few sec-
onds.
11
A maximum of 20 reading can be stored per alignment job. The current
alignment readings must be different from the previous set for the readings
to be recorded. If more than 20 readings are acquired a message is dis-
played giving you the option of either discard the last reading taken or
overwriting the 20th reading with the last reading.
Note
If you decide to overwrite the 20th reading with the last
reading, it cannot be retrieved.