User Manual

4-45
Attaching the Fixtures
Note
There will, of course, be combinations of the movements
shown in the previous table. However, these recommendations
should provide some general guidelines.
Partial Sweep Rough Alignment
In this method, you must use the fixtures and set the analyzer to Manual
Sweep or Auto Sweep mode. Either method can provide an effective target
area much larger than the 20 mm x 20 mm surface area. If the xtures can
be rotated and both beams remain on target
greater than 90°
(recom-
mended)
of the sweep, the analyzer can produce an alignment solution from
the data taken. Data gathered from the portion of sweep that laser beams
were off target is rejected. For more information about sweep data collec-
tion modes, see Chapter 6, Acquiring Alignment Data.”
Note
This procedure will also work when using the Dual Pass mode.