Manual Chapter 5

7-3
Alignment Setup
Alignment Setup
3
From the alignment application's main menu, press the Options function
key. Arrow the selection bar to Alignment Setup and press the Enter key.
The following screen is displayed.
4
Use any Number key to toggle through the selections for method until
straightness is displayed. Once this method is shown, use the Up and Down
Arrow keys to make a selection, and any Number key to toggle through the
options for that selection. If necessary, use these keys to set the Sample rate
and Collection mode.
Sample Rate –
determines the number of data samples that are to
be collected and averaged together to produce a single Laser PSD
reading. Use the Left and Right Arrow keys to toggle sample rate
from 1 to 25 samples. The default is 2.