Manual Chapter 5
5-39
View Data
10
To view the Acceptable and Excellent tolerances, press the Alt and Page Up
keys. To view all the reading sets at the optimum scale, press the Alt and
Page Down keys. To increase or decrease the scale by a factor of two, press
the Up and Down arrow keys.
Horizontal Log Display
Once you have reached the tolerance targets, your machinery should
operate correctly without any adverse effects from misalignment.
The offset and angle information is intended to be used as an alignment tol-
erance only (to determine how close the alignment is based upon the last
set of alignment readings); do not use this data to align the machines. For
this reason, offset and angle are always displayed as positive numbers.