Manual Chapter 5

5-24 Using UltraSpec Alignment - General Overview
If FDI is selected, the data is evaluated by default as follows:
“-----” – no measurement was made for this foot
“No Box” – excellent condition (less than 2.0)
“Clear Box” – acceptable condition (between 2.0 and 3.0)
“Dark Box” – out of tolerance (greater than 3.0)
These tolerances can be changed in UltraMgr and transferred to the UltraSpec.
Warning!
The numbers displayed are not the required correction
shims for this foot. Soft Foot corrections frequently
require wedge shaped arrangements of shims to be
installed. However, the actual thickness and shape of the
Soft Foot correction must be determined by using a feeler
gauge.
Note
For more information about Foot Pre-Check, see Appendix
heading “Foot Pre-Check Types” on page -1
Note
Remember that all this data is dumped to UltraMgr. Help mes-
sages are available if needed.