Manual Chapter 5
5-22 Using UltraSpec Alignment - General Overview
Foot Pre-Check
When Foot Pre-Check is selected (from the main menu) and the Job Defi-
nition screen is completed, a screen similar to the one below on the left will
be displayed. The screen that is displayed depends on the type of Foot Pre-
Check selected (Soft Foot or Frame Distortion Index [FDI]). For more infor-
mation, see the Appendix heading, “Foot Pre-Check Types” on page -1.
Use the Enter key to move to the Soft Foot/FDI Locator screen (on the
right). Ensure that the sensor heads are at the top (as shown) or, at the
bottom position (180°). After verifying that all hold-down bolts are tight,
press Enter to proceed to the Soft Foot/FDI Data screen shown below.
Use the Up/Down arrow keys to select the foot to be checked. In the screen
above, the right outboard foot of the generator has been selected. Press
Delete to start.