User`s guide

Control Hex Name
DC4 DC4 ESC ! NN 6 PP EM 14 14 1B 21 06 Select UPC 2-Digit Bar Code
(Magazine)
DC4 DC4 ESC ! NN 7 PP EM 14 14 1B 21 07 Select UPC 5-Digit Bar Code
(Magazine)
DC4 DC4 ESC ! NN 17 PP EM 14 14 1B 21 11 Select 2 of 5 INTERLEAVED Bar Code
DC4 DC4 ESC ! NN 18 PP EM 14 14 1B 21 12 Select 2 of 5 INDUSTRIAL Bar Code
DC4 DC4 ESC ! NN 19 PP EM 14 14 1B 21 13 Select 2 of 5 MATRIX Bar Code
DC4 DC4 ESC ! NN 20 PP EM 14 14 1B 21 14 Select CODE 3 of 9 Bar Code
DC4 DC4 ESC ! NN 22 PP EM 14 14 1B 21 16 Select CODABAR Bar Code
DC4 DC4 ESC ! NN 23 PP EM 14 14 1B 21 17 Select CODE 128 Bar Code
DC4 DC4 ESC ! NN 24 PP EM 14 14 1B 21 18 Select POSTNET Bar Code
DC4 DC4 ESC ( GS {N1} {DATA1} {N2} {DATA2}
EM
14 14 1B 28 1D
DD..DD 1D DD..DD 19
Print Bar Code Selection
DC4 DC4 ESC @ 14 14 1B 40 Reinitialize Printer
DC4 DC4 ESC 1 NN 14 14 1B 31 Set Vertical Spacing n/144 Inch
DC4 DC4 ESC 3 1 14 14 1B 33 31 Set Vertical Spacing to 12 Lines/30mm
DC4 DC4 ESC 3 3 14 14 1B 33 33 Set Vertical Spacing to 3 Lines/30mm
DC4 DC4 ESC 3 4 14 14 1B 33 34 Set Vertical Spacing to 4 Lines/30mm
DC4 DC4 ESC 3 6 14 14 1B 33 36 Set Vertical Spacing to 6 Lines/30mm
DC4 DC4 ESC 3 8 14 14 1B 33 38 Set Vertical Spacing to 8 Lines/30mm
DC4 DC4 ESC 5 14 14 1B 35 Eject Single Sheet or Form Feed
DC4 DC4 ESC A 14 14 1B 41 Set 15, 17.1, or 20 CPI
DC4 DC4 ESC N 14 14 1B 4E Load or Park Fanfold from a Rear Path
DC4 DC4 ESC T 14 14 1B 54 Load or Park Fanfold from a Front Path
DC4 DC4 ESC Y 14 14 1B 59 Select Emulation
DC4 DC4 ESC Z 14 14 1B 5A Select AFTA in Column
DC4 DC4 ESC g 14 14 1B 67 Select Resident Font
DC4 DC4 ESC h 14 14 1B 68 Request to Read Configuration
DC4 DC4 ESC h 14 14 1B 68 ..... Printer Configuration Response
DC4 DC4 ESC i 14 14 1B 69 ..... Write Configuration Response
DC4 DC4 ESC i 14 14 1B 69 Write Configuration Acknowledgement
DC4 DC4 ESC p 14 14 1B 70 Select Print Quality
Select EAN-8 Bar Code (DC4 DC4 ESC ! NN 1 PP EM)
14 14 1B 21 NN 01 PP 19
This control selects the EAN-8 bar code.
The DATA field must contain only ASCII numeric (0 to 9) data, and must be eight bytes long, check digit
included.