User`s guide
Table 9. IPDS Coding Example (continued)
IPDS Command Hexadecimal Code Code Explanation
— D62D Write Text
— 00 Flag Byte
— 2BD3 Escape Sequence
— 04C70E10 Absolute Move Inline
— 04D21518 Absolute Move Baseline
— F7F3F2F4F5 Data '73245'
WT 000E Control Length
— D62D Write Text
— 00 Flag Byte
— 2BD3 Escape Sequence
— 04C61AB8 Absolute Move Inline
— F0F9F9 Data '099'
WT 0013 Control Length
— D62D Write Text
— 00 Flag Byte
— 2BD3 Escape Sequence
— 04C628C8 Absolute Move Inline
— F1F262F1F661F8F6 Data '12/16/86'
******** Write Graphics Control
WGC 002C Control Length
— D684 Write Graphics Control
— 00 Flag Byte
(GAP) 000B Field Length
— AC6B Graphics Area Position Control
— 0000 Inline (X) Coordinate Position
— 0000 Baseline (Y) Coordinate Position
— 0000 Orientation (0 degrees)
— A0 Absolute X, Absolute Y
(GDD) 001C Field Length
— A6BB Graphics Data Descriptor
— 00 Unit Base (10 in.)
— 00 Reserved
— 3840 X Units/Unit Base
— 3840 Y Units/Unit Base
— 00000000 Reserved
— 0000 X Left Limit of Window
— 3570 X Right Limit of Window
— 1EF0 Y Top Limit of Window
Chapter 6. Print Samples and IPDS Coding Example 227