Installation guide

2-6
Bull S.A.May 25th, 1999
3. Bulldisk, Bulldisk_diag –
(Disks)
These packages provide software for Bull disks Differential and Single Ended Fast/Wide,
and Ultra/Wide. This software allows to use the functions of the AIX Diagnostics Subsystem
for Bull disks:
Disk diagnostics
From the Tasks and Service Aids diagnostics functions, access to format and certify
commands, and to disk error log report analysis.
Restrictions and Limitations
For all STxxx disks (in the upper table), the diag command format is aborted after some
time; run again the same command to format disk properly.
The mkvg command, after formatting STxxx disks, gives an error like: bad pvid....
Use the chdev command to give a new pvid:
# chdev –l hdiskX –a pv=yes
and perform the mkvg command again.
If you have already connected disks recognized as “Other SCSI Disk Drives”,
reboot the system after installing the Bulldisk package.
The lsdev command prints a 4.3 GB capacity for disk drives model ST3437X. This
value is a rounded value; the capacity usable under AIX is given by the lspv command.