User manual
146
Reliability
MTBF Mean Time between failure: 10000 hours at 25% DC
MTTR Mean Time To Repair: 30 minutes
Workload 60.000 pages/month (ECMA 132 - 4 hours for 20 days)
Printer Life 5 years or 10000 hours @25%
Duty Cycle Operating: no limitations
Power Supply
UNIVERSAL From 90 to 244 VAC
Power Output Max. 215 W
Power Consumption Standby: 28W ---- Average Printing: 90 W
Noise Level
< 55 dBA
Environment Conditions
Storage Conditions
Temperature -40° to 50° C
Relative Humidity 10%t o 90% RH (non condensing)
Operating Conditions
Temperature 10° to 38° C
Relative Humidity 10 % to 90 % RH (non condensing)