Specifications
CompuLab Ltd. IPC2 – Hardware Specification Page 74 of 83
9 Electrical Characteristics
9.1 Absolute Maximum Ratings
Operating the IPC2 under conditions beyond its absolute maximum ratings may damage the
device. Absolute maximum ratings are limiting values to be considered individually when all other
parameters are within their specified operating ranges. Functional operation and specification
compliance under any absolute maximum condition, or after exposure to any of these conditions,
are not guaranteed or implied. Exposure may affect device reliability.
Table 40 – Absolute Maximum Ratings
Parameter
Min
Typ.
Max
Unit
Main power supply voltage
8.5
-
16
V
9.2 Recommended Operating Conditions
Operating conditions include parameters that are under the control of the user: power-supply
voltage and ambient temperature. The IPC2 meets all performance specifications when used
within the recommended operating conditions, unless otherwise noted.
Table 41 – Recommended Operating Condition
Parameter
Min
Typ.
Max
Unit
Main power supply voltage
10
12
15
V
V5SBY – 5V power domain current
-
-
4
A
9.3 DC Electrical Characteristics
Table 42 – DC Electrical Characteristics
Parameter
Operating
Conditions
Min
Typ.
Max
Unit
3.3V Digital I/O
V
IH
SIO_GPIO
[15,16,30,31,35-37]
2.0
V
V
IL
0.8
V
V
OH
2.4
V
V
OL
0.4
V
I
OH
-4
mA
I
OL
8
mA
I
OL leakage
-10
10
µA
RS232
TX Voltage
Swing
±5.0
±5.4
-
V
Input Voltage
Range
-25
-
25
V