Product Manual

Wall Mounted Ultrasonic Flowmeter---User Manual
6
WARNING!
The flowmeter can be used to measure flow of many liquids. Some of the liquids may be
hazardous. It is important that user comply with local safety codes and regulations in
installing and using electronic devices in the area.
2.2.Installation Considerations
This section provides guidelines for installing the wall mounted transmitter and transducers.
2.2.1 Mounting Transmitter
The main unit electronics are housed in an IP68 (NEXA4X) weather-resistant and dust-tight
enclosure. There, the main unit can be installed indoors and outdoors. Usually, it is mounted in a
meter shed or on a location where one can easily access for meter testing and servicing. See the
following figure for detailed dimensions.
2.2.2 Installing Transducers
Firstly, you need to select a proper installation site. For this, one usually need to consider the
accessibility of the location, operating space needed for the installation, safety code compliance,
etc. In addition, flow and pipe conditions near the installation site are also very important.
For detailed transducers installation, please refer to transducers installing guide manual
separately.