Product Manual
Wall Mounted Ultrasonic Flowmeter---User Manual
5
Clamp-on type Standard S1 for 1”~4”(DN25-DN100mm)
Standard M1 for 2”~28”(DN50-DN700mm)
Standard L1 for 11”~240”(DN300-DN6000mm)
High temperature S1H for 1”~4”(DN25-DN100mm)
High temperature M1H for 2”~28”(DN50-DN700mm)
Insertion wetted type For 3”~240”( DN80-DN6000mm)
Flow-cell inline type For DN15-DN1000mm
Protection Class Transducers: IP68
Transducer
temperature
Standard clamp-on type: 0"~70"
High temperature clamp-on type: 0"~150"
Insertion wetted type: 0"~150"
Flow-cell inline type: 0"~150"
Transducer cable Shielded transducers. Standard length 15’(5m).Can be extended to
1640’(500m).Contact the manufacture for longer cable requirement.
Cable should not be laid in parallel with high-voltage power lines,
neither should it be close to strong interference source such as power
transformers.
LIQUIDS
Liquid Types Virtually all commonly used clean liquids.
Liquids with small quantity of tiny particles may also be applicable.
Particle size should be less than 100um, particle concentration less than
20,000ppm or<2%.
Liquid should contain no or very minor air bubbles.
Liquid Temperature -40"~155" depending on transducer type
Pipe
Pipe size DN25-DN6,000mm(0.5”~240”)
Pipe material All metals, most plastics, fiber glass, etc. Allow pipe liner
Straight pipe section 15D in most cases, 30D if a pump is near upstream, where D is pipe
diameter
Chapter 2.Installing and Measurement
2.1.Unpacking
Please unpacking the shipping box and check the parts and documents against the packing slip. If
there is something missing, the device is damaged or something is abnormal, please contact us
immediately and do not proceed with the installation.