Product Manual
Wall Mounted Ultrasonic Flowmeter---User Manual
21
M93 Dis
p
la
y
s total transit time and delta time
(
transit time difference
)
M94
Displays the Reynolds number and the pipe factor used by the flow rate measurement
program. Pipe factor is calculated based on the ratio of the line-average velocity and the
cross-section avera
g
e velocit
y
.
M95
(1) Display the positive and negative energy totalizers
(2) Upon entering this window, the circular display function will be started automatically.
The following windows will be displayed one by one, each window will stay for 8
seconds: M95>>M00>>M01>>M02>>M02>>
M03>>M04>>M05>>M06>>M07>>M08>>M90>>M91>>M92>> M93>> M94>>M95.
This function allows the user to visit all the important information without any manual
action.
To sto
p
this function, sim
p
l
y
p
ress a ke
y
. Or switch to a window other than M95.
M96 This is not a window but a command for the thermal
p
rinter to advance 5 lines of
p
a
p
er.
M97
This is not a window but a command to print the pipe parameters.
By default, the produced data will be directed to the internal serial bus (thermal printer).
You can also direct those data to the serial communication
p
ort.
M98
This is not a window but a command to print the diagnostic information.
By default, the produced data will be directed to the internal serial bus (thermal printer).
You can also direct those data to the serial communication
p
ort.
M99
This is not a window but a command to copy the current display window. By default, the
produced data will be directed to the internal serial bus (thermal printer). You can also
direct those data to the serial communication port.
By use of the window copying function, you can hardcopy very window displaying
manually by switching windows, or you can obtain the window displaying data by
communication.
M+0
Browse the 32 recorded instrument power-on and power-off date and time with the flow
rate at the time of
p
ower on and off
M+1
Displays the total working time of the flow meter.
When the backu
p
batter
y
is removed, the total workin
g
time will be reset to zero.
M+2 Dis
p
la
y
s the last
p
ower-off date and time
M+3 Dis
p
la
y
s the last
p
ower-off flow rate
M+4 Dis
p
la
y
s how man
y
times of has been
p
owered on and
p
owered off.
M+5
A scientific calculator for the convenience of field working.
All the values are in single accuracy.
The calculator can be used while the flow meter is conducting flow measurement.
Water densit
y
and PT100 tem
p
erature can also be found in this function.
M+6
Set fluid sound speed threshold
Whenever the estimated sound speed (displayed in M92) exceeds this threshold, an alarms
signal will be generated and can transmitted to BUZZER or OCT or RELAY.
This function can used to
p
roduce an alarm or out
p
ut when fluid material chan
g
es.
M+7 Dis
p
la
y
s total flow for this month
(
onl
y
for the time
p
ast
)
M+8 Dis
p
la
y
s total flow for this
y
ear
(
onl
y
for the time
p
ast
)
M+9
Display the not-working total time in seconds. The total failure timer will also include the
time when
p
ower off, if the back-u
p
batter
y
is a
pp
lied.
M.2 Entr
y
to solidif
y
the zero
p
oint. Password
p
rotected.
M.5 Setu
p
the Q value threshold.