Product Manual
Wall Mounted Ultrasonic Flowmeter---User Manual
13
Menu
window
No.
Function
M00
Display flow rate and NET totalizer
If the net totalizer is turned off, the net totalizer value shown on the screen is the value
prior to its turn off
Select all totalizer unit in menu M31
M01 Display flow rate, velocity
M02
Display date time and POS(positive) totalizer
If the positive totalizer is turned off, the positive totalizer value shown on the screen is the
value
p
rior to its turn off
M03
Display flow rate and NEG(negative) totalizer
If the negative totalizer is turned off, the negative totalizer value shown on the screen is the
value
p
rior to its turn off
M04 Display date and time, flow rate. The date and time setting method is found in MENU60
M05 Display energy rate(instantaneous Caloric)and total energy (Caloric)
M06 Display temperatures, inlet T1, outlet T2
M07
Display analog inputs, AI3/AI4, current value and its corresponding temperature or
pressure or liquid level value
M08
Display all the detailed error codes
Display working condition and system error codes. ‘R’ stands for normal; others refer to
Cha
p
ter 5 for details.
M09 Display today’s total NET flow
M10
Window for entering the outer perimeter of the pipe
If pipe outer diameter is known, skip this menu and go to Menu 11to enter the outer
diameter
M11
Window for entering the outer diameter of the pipe. Valid range: 0 to 18000mm.
Note:
y
ou
j
ust need to enter either the outer diameter in M11 or the
p
eri
p
heral in M10
M12
Window for entering pipe wall thickness
You ma
y
ski
p
the menu and enter inner diameter in M13 instead.
M13
Window for entering the inner diameter of the pipe
If pipe outer diameter and wall thickness are enter correctly, the inner diameter will be
calculated automaticall
y
, thus no need to chan
g
e an
y
thin
g
in the window
M14
Window for selecting pipe material
Standard pipe materials (no need to enter material sound speed ) include:
(0) carbon steel (1) stainless steel (2) cast iron (3) ductile iron (4) copper
(5) PVC (6) aluminum ,(7) asbestos (8) fiberglass
(
9
)
other
(
need to enter material sound s
p
eed in M15
)
M15 Window for entering the pipe material speed, only for non-standard pipe materials
M16
Window for selecting the liner material, select none for pipes without any liner.
Standard liner materials
(
no need to enter the liner sound s
p
eed
)
include: