Operating instructions
8
CHROMOPHARE
®
D 650plus, D 530plus,D 300, C 95x Operating instructions (E)
2.3 Installation instructions
Mounting and installation of the CHROMOPHARE
®
lights must be in accordance with BERCHTOLD’s
“Mounting instructions for ceiling lights” and must only be performed by BERCHTOLD employees or by instal-
lation companies authorized by BERCHTOLD. The installation of lights on the ceiling of the operating room
must be performed in accordance with BERCHTOLD’s “Ceiling anchor plate and spacer block” mounting in-
structions due to weight and high torque.
Incorrect assembly of the lights can result in ceiling anchorage damage off and falling down, critically injuring the
patient and operating staff in the process. The on-site electric installation must be performed in accordance with
IEC 60364-710 and include a fuse protection as well as a mains switch for a simultaneous all-polo separation of
the light. For further information, please note the mounting instructions.
2.4 Instructions for initial start-up
The operator may begin to use the light, after the manufacturer or supplier:
a) Has carried out a performance check at the place of operation,
b) has introduced those responsible for the operation of the light to its correct handling by means of the user’s
manual.
2.5 Visual and performance check
Before initial start-up the manufacturer or supplier should check that the CHROMOPHARE
®
light has been
properly installed and is in a safe and operational condition.
A visual inspection of the following points must take place:
• After switching-on the unit, light must be emitted from the main lamp, and in the case of combination lights,
also from the additional lamp.
• Inspection of the light emission lens of the lamp housing.
If the light emission lens is damaged or broken, glass splinters can fall out. The light must be switched off im-
mediately and must not be used until the defect has been rectified.
• Inspection of the reserve lamp warning indicator CHROMOPHARE
®
C 95x
In the case of failure of the main lamp, the reserve lamp is automatically switched on: The red warning indicator
on the keyboard illuminates to indicate this error. The defective main lamp must be replaced immediately.
• Inspection of the reserve lamp warning indicator CHROMOPHARE
®
D Generation
In the case of failure of the main lamp, the reserve lamp is automatically switched on and swung into the posi-
tion of the main lamp. The yellow warning indicator on the lamp housing illuminates to indicate this error. The
defective main lamp must be replaced immediately.
• Checking the operational state of the control unit.
The individual functions must be checked by activating the appropriate keys. Faults in the main circuit of the
control electronics of the CHROMOPHARE
®
D 650 and D 530 are indicated by the red fault indicator on the
control unit. In this case the light operates at its maximum luminous intensity and can no longer be controlled
via the keys.
• Checking the movement mechanism for perfect operation.
The mechanical operation of the lightsystem is checked by swiveling and rotating the movement mechanism.