Technical data

50 / 60 HBC-series V7 LV small types profi low power
NEUTRAL = STOP
MIN = STOP
Start with programmed throttle limits
a) Type of controller’s start (parameter P5) is set to „Safety start“ (default value) or „Fast start“.
In the parameter P4 Control signalis set “Programmed“ or some possibility of Programmed, parameters II ( under line ====== )
Controller remembers set throttle limits.
1) Turn on control signal source. Joystick
(potentiometer, control voltage, …) is in position
STOP:
= neutral for joystick with neutral
= min. throttle for joystick without neutral
If not the joystick in the STOP position, the controller waits for the joystick (potentiometer, control voltage, …) to move to this posi-
tion, before the engine cannot run. The controller indicates the position of the joystick by LED indication:
- signal is above neutral position, controller wait for Neutral..…….…….
- signal is bellow neutral position, controller wait for Neutral..………….
2) Turn on controller, wait for blue LED + yellow LED continuous lights + melody …………..
3) You can start now (controller is ready to run).
b) Type of controller’s start (parameter P5) is set to „Immediate start .
In the parameter P4 Control signal is set “Programmed“ or some possibility of Programmed, parameters II ( under line ====== )
Controller remembers set throttle limits.
1) Turn on control signal source. Joystick
(potentiometer, control voltage, …) is in any position
(any signal value).
The controller does not check joystick
position (if joystick is in the STOP position)
after turn-on !!!
2) Turn on controller, when lights blue LED + other LEDs by current value of driving signal.
! WARNING ! MOTOR START IMMEDIATELY run with PWM (rpm, torque) corresponding with driving signal ! WARNING!
Signal source with Neutral position
Signal source without Neutral position
0.15 V
(1 ms)
+1.65 V (1.5 ms)
+3.15 V
(2 ms)
STOP position
100% backward
100% forward
0.15 V
(1 ms)
+1.65 V (1.5 ms)
+3.15 V
(2 ms)
STOP position
100% forward
STOP position
čekej
Signal source with Neutral position
Signal source without Neutral position
0.15 V
(1 ms)
+1.65 V (1.5 ms)
+3.15 V
(2 ms)
STOP position
100% forward
0.15 V
(1 ms)
+1.65 V (1.5 ms)
+3.15 V
(2 ms)
100% backward
100% forward