Technical data

48 / 60 HBC-series V7 LV small types profi low power
b) By control signal source - set corresponding limits at any time direct by the signal source (even without connection to PC).
Parameter P33 "Setting from transmitter" must be set to "Enabled“.
Parameter P4 "Control signal" is set to „Programmed“.
 Signal sources with NEUTRAL (with lock of STOP position)
(position STOP is identical with the position „Neutral“ )
1) Turn on control signal source with joystick
(potentiometer, control signal, …) in position
full throttle forward“. Turn on controller.
2) Controller short beep 3× by motor, blue LED and
green LED lights.
After 10 seconds controller 3× long beeeps.
3) You have 3 seconds now to move the joystick to
max. throttle backwards (=full brake)
If in this time limit you do not change the control
signal value, the programming process will be fin-
ished and the controller will be turned off. Its next
operation is possible after switching off and then
turning it on again.
4) If you start moving joystick in this time limit 3 sec. to
max. throttle backward position, controller lights red
LED and after stop in outer position (max. throttle
backward) 2× long beeeps.
5) Controller lights yellow LED (challenge to moving to
STOP position). You have 3 seconds now for mov-
ing throttle to Neutral position (=STOP).
6) Controller confirm correct finishing of this operation
by 1× blink together by red LED, yellow LED and
green LED and play melody.
7) Controller starts blinking by blue LED (others
LEDs not light) necessary switch-off controller.
Throttle limits of your controller corresponding with throttle limits of your transmitter and controller remember these values.
 Signal sources without NEUTRAL (without lock of STOP position)
(position STOP is identical with the position „Min. throttle “ )
1) Turn on control signal source with joystick (potentiometer, control
signal, …) in position „full throttle forward “.Turn on controller.
2) Controller short beep 3× by motor, blue LED and green LED lights.
After 10 seconds controller 3× long beeeps.
3) You have 3 seconds now to move the throttle to min. throttle (=STOP)
If in this time limit you do not change the control signal value, the
programming process will be finished and the controller will be
turned off. Its next operation is possible after switching off and then
turning it on again.
4) If you start moving joystick in this time limit 3 sec. to min. throttle
position, controller lights red LED and after stop in outer position
(min. throttle) 2× long beeeps.
5) Controller lights yellow LED (challenge to moving to STOP position).
You have now 3 second for moving throttle to STOP position. Leave
the joystick in position min. throttle (= STOP) at least 3 seconds.
6) Controller confirm correct finishing of this operation by 1× blink
together by red LED, yellow LED, green LED and play melody.
7) Controller starts blinking by blue LED (others LEDs not light) necessary switch-off controller.
Throttle limits of your controller corresponding with throttle limits of your transmitter and
controller remember these values.
Full throttle forward
Full throttle backward
NEUTRÁL
10 sec.
<3 sec.
!
<3 sec.
!
Throttle limits correspond-
ing with control signal
0.15 V
(1 ms)
+1.65 V (1.5 ms)
+3.15 V
(2 ms)
Neutral=STOP
forward
backward
100% backward
100% forward
STOP position (NEUTRAL)
Full throttle
Min. throttle
Min. throttle
10 sec.
<3 sec.
>3 sec.
!
Throttle limits correspond-
ing with control signal
½ throttle
max. throttle
min. throttle
(=STOP)
0.15 V
(1 ms)
+1.65 V (1.5 ms)
+3.15 V
(2 ms)
STOP position
100% forward
½ throttle