Technical data

39 / 60 HBC-series V7 LV small types profi low power
View from
opposite side
to USB port in PC
connector ICS-2
CC_11
Connection cable CC_11
EFRA connector
EFRA connector
connect to ICS-2
HBC-series controller
Detail, view „from
motor side“
connector ICS-2
A
B
C
A
B
C
Parameters setting / Data reading from controller
To set parameters or reading data from the controller, you need to connect your PC and the controller module USBCOM 4 or USBCOM 4i
(for the controller feeding from the mains power supply), the PC software "Controller 2", which is free to download from our web and on CD
and need connecting cable CC_11.
.
1) start program Controller 2
2) connect USBCOM 4(i) module to USB port of your PC and connect with controller by CC_11 cable (cable CC_11 is connected to ICS-2
marking connectors, in both equipment)
3) turn on controller by connect to suitable battery (and turn-on switch for version with switch)
4) now you can communicate with controller, read data, change parameters value, write changes parameters etc.
Don´t forget select memory bank first, change parameters after this. Before switch-off write parameters by buttonWrite setting.
Important: If the controller is feed from the battery, module USBCOM 4 is enough to connect of the controller to the PC. But if you
need use power supply for feeding the controller, you must use module USBCOM 4i, which ensure galvanic isolation of
the controller from the PC. This is necessary because a number of mains power supply (either in PC or others) is not ful-
ly correct separated from their chassis (minus their potentials, GND) and is possible measured frequently large voltage
(units to tens of volts). If you apply in this case USBCOM 4 non-insulated module, you risk damaging or destruction as
USBCOM 4 module, as well as also the controller (or USB port on your PC).
Program Window
in the PC screen:
Shift to other parameters
hidden below and up
controller type and
version
Language select
Main control
Parameter value
set as number
Select from
possibilities
parameters
setting area
„Analog“
value setting