Technical data
29 / 60 HBC-series V7 LV small types profi low power
P4: Control signal
Driving signal can be:
- input PWM (pulse width 1 ÷ 2 ms, period 3.5 ÷ 30 ms, signal pulse level 0 ÷ 3,3V or 0 ÷ 5V)
- voltage 0 up to +3,3V resp. 0 up to +5,0V (or other range)
- potentiometer 1kΩ (resp. 5kΩ or 10kΩ)
- logic signal, value 0 to +3,3V resp. 0 to +5,0V, read contact, etc.
- data transfer
Note: Main channel for control signal by input PWM is port „INP_1“, auxiliary port is „INP_2“
Main channel for control by voltage (or potentiometer) is port „INP_2“, auxiliary port is „INP_1 “
I)
PWM automat (throttle limits is necessary set for each turning on controller)
PWM programmed (controller use saved learned throttle limits)
===========================================================================
II) (controller always remember throttle limits)
PWM main channel (= input INP_1)
PWM channel 1+2 (main channel + auxiliary channel)
PWM channel 1-2 (main channel - auxiliary channel)
PWM separate throttle / brake
Voltage main channel (=input INP_2) (or potentiometer)
Voltage channel 1+2 (main channel + auxiliary channel)
Voltage channel 1-2 (main channel - auxiliary channel)
Voltage, separate throttle / brake
Logic signal
Data transfer UART (RS-232)/(RS-485)
Data transfer CAN
Data transfer TWI
This parameter coheres with next parameters P6, P7 and P8 , resp. P9, P10 and P11.
I) In case PWM automat is advantageous because you do not have to set or program anything even when you change the transmitter setting
(on channel throttle) or use different transmitter or receiver (driving signal). The disadvantage is that you have to show the controller the
throttle limits after each turn on of the controller by moving the throttle forwards and backwards, respectively minimal and maximal throttle.
In most cases is better when controller remember real throttle limits. Necessary set this parameter to “PWM Programmed” and learn real
throttle limits by way description for next parameters (P6, P7, P8).
II) In case „PWM main channel“ and next parameters, (i.e. parameters II), under line ====), is necessary directly set values for parameters
P6, P7 a P8, resp. P9, P10 a P11 by program Controller 2. This way parameters set not possible change by some other method (as pos-
sible for parameters I). Controller remembered these values.
P33: Control signal limits setting lock (by signal source)
forbidden - blocks of unwanted rewriting of throttle limits (blocks “learning” of these values)
allowed - permits learning of throttle limits (rewriting of parameters P6, P7, P8) from signal source
P90: Monitoring limits for voltage control
Parameter off limits of the analog input voltage 0.15 V and 3.15 V - when above and below this value, the input voltage is evaluated as "out of
range" (Prohibited area L). Related to monitoring of disconnection control signal / cut potentiometer. When set to "off" prohibited areas are disa-
bled and deactivated and the input signal can be in the full range 0.0 to 3.3 V.
off
on