Technical data

16 / 60 HBC-series V7 LV small types profi low power
Control and additional control by logic signals
Control by logic signal (function A).
The controller can be operated only by logic signal (on / off), applied to the control input "INP_1". Speed (power, torque, etc.) in the on posi-
tion can be defined by setting the parameters P19, P20, P50 (various limits) or the engine goes to the full power. The speed of acceleration
ramp is again given by parameter P16 “Acceleration”.
Enabling engine running by logic signal (function B).
In case you need switch on / off running of the engine by switch, contact or logical signals, but the speed (power, PWM, ...) are managing by
signal at the input "INP_1" or "INP_2", auxiliary permitting input (gate) is always carried by the second (for control unused) input or INP_2
INP_1. This gate (permitting) function can be activated by parameter P41.
If necessary, this permitting signal (gate) may be also moved to another port, of course, if it is free and available, this is customization.
Start the controller after turning on is determined partly by setting P5 (safe, fast, immediate), second by the logical state of the control signal
and, if selected "function B" also level of the main control signal (voltage, input PWM, potentiometer).
Galvanic non-isolated control input: Galvanic isolated control input:
In the event that both inputs INP_1 and also INP_2 used for control, it is possible to move the gate function to the input TxD and activate by pa-
rameter P41. The same time it must be defined in order (normally the port is used as the output port for communication in HW).Of course, if this
function is used, you cannot use the communication channel RS-232 TTL.
Control motor rotation direction by logic signal (P54).
The direction of rotation of the controller can be independently controlled by by logic signal (one direction / opposite direction) on the RxD in-
put. This must also correspond with the settings of the parameter P54.
Galvanic non-isolated control input: Galvanic isolated control input:
Of course, if this function is used, you can not use the communication channel RS-232 TTL.
0V
+2.4 to 5V
GND
+3.3V
Switch, read contact,
TTL signal,
resp. voltage 0 up to 24V
Controller HBC- series
INP_1
switch, opto-
coupler, transis-
tor, …
+
optical isolation
Controller HBC- series
Control signal
INP_1
+
optical isolation
Controller HBC- series
0V
+2.4 to 5V
Control signal
RxD
GND
+3.3V
Switch, read contact,
TTL signal,
resp. voltage 0 up to 24V
Controller HBC- series
RxD
switch, opto-
coupler, transis-
tor, …
GND
+3.3V
Switch, read contact,
TTL signal,
resp. voltage 0 up to 24V
)
Controller HSBC- series
TxD !
switch, optocoupler,
transistor, …
.