Technical data

14 / 60 HBC-series V7 LV small types profi low power
Control by data transfer.
When controlling is realized by data transfer, following possibilities can be choice:
- standard line RS 232 or bus RS 485 or CAN (also optically insulated see specification)
- or RS 232 line with TTL level (advantage fr direct communication processor processor). Controller cooperates with 3.3V systems, as well
as with 5V systems. In this case line is defined like this:
Controller sends data with 3.3V level.
Controller receives correctly data from control system with 3.3V level, as well as 5.0V level.
Control by input PWM.
Control signal definition:
Control information is Pulse width.
Controllers without galvanic isolation for input PWM:
Controllers with galvanic isolation for input PWM:
GND
+3.3V
(voltage +5V)
input PWM
Internal DC/DC converter (+5V)
Possible supply for generator, receiver, system, ..
(the order of mA)
Controller HBC- series
Control signal generator
Receiving of input PWM
control PWM for controller 3.3V or 5V
(3.3V or 5.0V logic)
Start bit
Stop bit
(1 or 2)
Data bits
Start bit
0 up to 0.8V
(log. 0)
+2.4 up to +3.3V (5.0V)
Quiescent state
(log. 1)
frame 1 byte
GND
GND
RxD
TxD
+3.3V
TxD
RxD
Data sending with
level 3.3V
Controller HBC- series
Control system
Data receiving from
control system
100 Ω
100 Ω
(3.3V or 5.0V logic)
0V / GND
+2.4 up to 5V
period
Pulse Width
(2.5 30 ms)
(1 2 ms)
GND generátoru
Optical insulation
+5V
driving PWM
+5V (feeding of controller’s optocoupler)
Controller HBC- series
Receiver or signal generator
control PWM for controller 3.3V or 5V
(3.3V or 5.0V logic)
GND, generator ground potential
Controller ground
potential
Receiving of input
control PWM