Technical data

10 / 60 HBC-series V7 LV small types profi low power
Marking and Specification of the HBC controllers / allowed combination
Marking of HBC_AAAVV_V7 HBC-series Controllers - specification of options for ordering
Meaning of the specifications: AAA nominal current/ VV max. feeding voltage
Sample: TMM 10063-3 V7 HBC
AAA = 100 max. continuous current 100A (nominal)
VV = 63 max. feeding (traction) voltage 63V=
Switching DC/DC converter
Controllers up to 35V is possible order with internal integrate switching DC/DC converter. Output voltage of this converter can be used for sup-
ply (feeding) of cooperating equipment.
Current rating of BEC declines with higher temperature. DC/DC converter current rate is 2A continuously for 25°C and 6A for short time current
peak. Short circuit on the output is tolerate some time without damaging.
Output voltage 5V, 6V, 7V and 8V is possible set in parameter P40.