User`s manual

ADVANCED STRAIGHTNESS
MEASUREMENT
INTRODUCTION
In the Advanced Straightness Measurement program straightness can be
measured in two axes. The laser beam is used as reference and the deviation
in distance between the laser beam and the measurement object is measured
in two or more positions, with the use of the receiver.
Measurement methods
In the Advanced Straightness Measurement program there are different
measurement methods. Measurement method is selected in the application
set-up.
Standard Straightness. The laser beam is set roughly
parallel to a surface or an object. Two points are used
as references.
The laser beam is set to level. One point is used as
reference.
Straightness with rotational center as reference (rotate
laser transmitter). The laser beam is representing an
axis of rotation. One point is used as reference. The
laser transmitter is rotated 180 degrees in each
measurement point to find the axis of rotation.
Straightness with center of bore as reference (rotate
receiver). The laser beam is set roughly parallel to a
center line. Two points are used as references. The
receiver is rotated 180 degrees in each measurement
point to find the center of the measurement object.
87