User`s manual

centre, mount the revolving bracket as in 7c or with the chain
fixture. Use the extension fixture and the rods.
If the movable machine does not have a tapped hole and cannot be
rotated, mount the lapped steel bar with the revolving bracket in its
centre.
Mount a target and an extension bracket on each revolving bracket and then
mount the rods. Use the long rods in order to slide the TD-units above the
targets.
PRE-ALIGNMENT FUNCTIONS
In the efforts to obtain the best possible conditions for a shaft alignment it is
necessary to check whether the shafts are bent, the machine base is warped
or if there is a soft foot condition.
The Basic Straightness program is primarily designed for
measurement of shaft and base straightness. See the chapter
Basic Straightness measurement.
The Softcheck function makes it possible to check softfoot
condition. See the chapter Softcheck.
START THE PROGRAM
Start the program by touching the Cardan Shaft Alignment
icon in the Main Menu.
Go to the Application Set-up for settings.
62