User`s manual

Tolerance table
Displays a table with most often used
tolerances. Metric or Imperial display depending
on settings for displayed units.
Contrast
Touching respectively on each side of the
symbol increases and decreases the screen
contrast.
Backlight
Turns on and off the screen backlight.
Confirmation
Confirms made selections and returns to the
application program.
MOUNTING & POSITIONING
Draft Procedure for Mounting OL2R Fixtures on a Horizontal Shaft Machine.
Choose a location on the main body of the machine (bearing housings or
adjacent casing) where the fixtures can maintain a clear line-of-sight and
the TD-units can be rotated 9, 3 and 12 o’clock without the cable/s
binding on adjacent structures. The brackets should ideally be arranged
as a mirror image of the machine.
Obtain proper permission to drill and tap a 6M thread (or 1/4” UNC) x 15
mm deep for each tooling ball on a flat surface, or glue a Fixturlaser
OL2R adapter on to the machine housing when it is not possible to drill.
Fix the tooling ball ensuring that the bolt is as tight as possible using an
allen key.
The following procedure should be followed to ‘cone-in’ each TD in turn
to the fixture target on the opposite end.
Mount the TD-S on what is determined as the Stationary side
fixture. Rotate it to 9 o’clock using the bubble on the side of
43