User`s manual
MOUNTING
Attach the V-block fixtures on the shafts of the measurement object, one on
each side of the coupling. Tighten the tension screws firmly, always using the
supplied tool. Do not over-tighten. Mount the rods to the fixture and tighten
firmly. Attach the TD-units on the fixtures. The TD-M should be mounted on
the moveable machine and the TD-S on the stationary machine. If the shaft
diameter is too large the chains can be extended with the optional extension
chains.
Connect the cables between the display unit and the TD-units. There are two
ways you can do this:
1. Connect one cable between the display unit and one of the TD units.
Then connect the second cable between the TD-units.
2. Connect one cable from one of the terminals on the display unit to
one of the terminals on TD-M. Then connect the second cable from
the other terminal on the display unit to one of the terminals on TD-
S.
You can use any of two terminals on each unit. If, for any reason, you detach
a cable during measurement you will need to return to the main menu and
then restart the measurement program.
22