ROLL MEASUREMENT
Select Roll measurement in the Roll Parallelism Program. The
screen shows the roll viewed from the driver’s side.
Touch the ID icon and enter the Roll ID. (This is mandatory).
You can use 8 alphanumerical characters. Touch OK.
Measure the distance between the positions on the roll, where
you are going to take readings. Touch the “A” symbol and
enter the distance (mm or inch depending on system
settings). Touch OK. If you have chosen to display the result
per roll length you will also need to enter the B value (roll
length).
Position the Detector on one of the desired measurement
points. Adjust the Detector angle so it is leveled using the
inclinometer display on the screen or, until the LED on the
Detector turns from flashing green to red, or vice versa.
Direct the laser beam to the Detector by rotating the turret
on the Angular Prism. Touch the icon corresponding to the
Detector position.