User`s manual

STRAIGHTNESS WITH MULTIPOINT
For complete description see also standard straightness.
Coarse adjustment
1. Place the receiver at the first bore with the fixture at 6 o´clock.
2. Locate the approximate centre of the bore with a tape measure and place
the receiver at this centre.
3. Position the laser transmitter as close as possible to the first bore so that
the laser beam hits approximately 2 mm under the centre of the target.
4. Move the receiver to the last bore. (If this bore has another diameter than
the first one adjust the receiver as in step 2.) Adjust the angle of the laser
beam with the adjustment screws so it hits approximately 2 mm under the
centre of the target.
5. Move the receiver to the first measurement point.
If the laser beam does not hit approximately 2 mm under the centre of the
target repeat step 2-5.
113