User guide
ENTEGRIS, INC. Customer Service Tel. 763-502-0200 Customer Service Fax 763-502-0300 49
NT® INTEGRATED FLOW CONTROLLER WITH DEVICENET™ COMMUNICATION USER GUIDE
ATT. RE- SUP- ACCESS DATA ATTRIBUTE
ID QUIRED PORTED RULE NV NAME TYPE DESCRIPTION VALUES
5 Optional Yes Set NV Calibration SHORT ASCII text, max 50 [default] = Null
Name STRING characters, User
accessible string
representation
used to identify
the calibration
or application.
6 Optional Yes Get NVF Full Scale STRUCT of: Full scale of the [default] = 0, 0
device using this
object instance
REAL Amount
ENGUNITS Units
SERVICES 64.1 - INSTANCE SERVICES - S-SENSOR CALIBRATION OBJECT 1
RE- SUP- PARAMETER
CODE QUIRED PORTED NAME PARAMETERS DESCRIPTION VALUES
0E
hex
Required Yes Get_Attribute_ Attribute ID Retrieves an 1–255
Single (USINT) attribute value
10
hex
Required Yes Set_Attribute_ Attribute ID Sets an Attribute ID = 1–255
Single (USINT); Value attribute value Value = attribute
specific
ENT48906 10/15/04 8:12 AM Page 49