User guide
ENTEGRIS, INC. Customer Service Tel. 763-502-0200 Customer Service Fax 763-502-0300 29
NT® INTEGRATED FLOW CONTROLLER WITH DEVICENET™ COMMUNICATION USER GUIDE
DeviceNet
TM
Object (03
hex
)
Class
ATTRIBUTES 3.0 - CLASS ATTRIBUTES - DEVICENET™ OBJECT
ACCESS DATA ATTRIBUTE
ATT. ID REQUIRED SUPPORTED RULE NAME TYPE DESCRIPTION VALUES
1 Optional Yes Get Revision UINT Object revision = 02
SERVICES 3.0 - CLASS SERVICES - DEVICENET™ OBJECT
PARAMETER
CODE REQUIRED SUPPORTED NAME PARAMETERS DESCRIPTION VALUES
0E
hex
Required Yes Get_Attribute_ Attribute ID Retrieves an 1–255
Single (USINT) attribute value
Instance 1
ATTRIBUTES 3.1 - INSTANCE ATTRIBUTES - DEVICENET™ OBJECT 1
ATT. RE- SUP- ACCESS DATA ATTRIBUTE
ID QUIRED PORTED RULE NV NAME TYPE DESCRIPTION VALUES
1 Optional Yes Get
*
NV
*
MACID USINT Node address = 0–63
2 Optional Yes Get
*
NV
*
Baud Rate USINT Baud rate 0 = 125K
1 = 250K
2 = 500K
3 = undefined
3 Optional Yes Get NV BOI BOOL Bus-off 0 = Hold bus-off
interrupt [default]
1 = Auto reset
(not supported)
5 Required Yes Get V Allocation Struct of: See service
Info BYTE Allocation Choice parameter
USINT Masters MACID
6 Required Yes Get V MACID BOOL Changed since 0 = No change
Swt Chg last reset 1 = Changed
(media access)
7 Required Yes Get V BAUD BOOL Changed since 0 = No change
Swt Chg last reset 1 = Changed
(media access)
8 Required Yes Get V MACID USINT Actual switch 0–99
Swt Chg value
9 Required Yes Get V BAUD USINT Actual switch 0–9
Swt Chg value
* If the corresponding configuration switch is higher than the attribute's limit, the attribute has SET access.
ENT48906 10/15/04 8:12 AM Page 29