Commissioning & Operation 2-2 Commissioning
The power unit should only be set down on
a level surface with adequate clearance (3ft
recommended) on all sides of the unit to al-
low for maintenance and service. Surfaces
should provide adequate vibration and deec-
tion prevention, as well as providing a suf-
cient load rating to support the full weight of
the power unit.
Distance from equipment to be powered
should be factored in, and all hydraulic hoses
and miscellaneous cables should be of suf-
cient length as to not place undue stress on
outlets.
Avoid placing the power unit directly on sur-
faces that are constantly wet as to prevent
added potential for unit frame corrosion.
Lifting of the power unit should always be
performed by using either the pad eye lifting
mounts located at the top of the frame or the
forklift lifting slots located at the base of the
frame.
When lifting with cables attached to the pad-
eye lifting mounts, lifting should only be per-
formed with all four (4) points bearing the load
evenly in a stable, level manner. Any sling or
lifting device and associated rigging equip-
ment should be, at minimum, rated to lift the
total weight of the power unit multiplied by a
factor of two (2). Refer to unit’s specications
manual for approximate weights.
For additional information regarding proper
rigging and overhead lifting , refer to OSHA,
ASME B30.9-2006. For additional information
on load bearing devices, see OSHA 1910.184,
ANSI/ASME B30.9 ”SLINGS”, ANSI/ASME
B30.10 ”HOOKS” and ANSI/ASME B30.26
“RIGGING HARDWARE”.
All load bearing devices provided are tested
to 1.5x - 2x their reported carry weight and are
issued certication tags. It is the responsibility
of the end user to re-certify these devices at
regular intervals (maximum 9 months as per
AUWED 95/63/Ec (LOLER) in the EEA) to as-
sure maximum safety.
2-2.2 Moving and Placing the Unit
WARNING
Any load bearing device that is observed to
have visible damage or is otherwise compro-
mised must be immediately removed from
service until it can be repaired or replaced.
(side view)
36”
(0.9m)
(top view)