Dimmer Log Screen
Pressing the [REPORT] key and the {DIMMER LOG} softkey will display the Dimmer Log screen
comprising a scrolling display showing a maximum of 200 date stamped fault reports in
chronological order. The log is automatically updated.
The log shows the date and time that each fault occurred, the rack and dimmer number and a
description of the fault. The lower portion of the screen shows a map of all configured racks (max.
99) colour-coded as follows to show their status:
Green: Online
Red: Fault on rack, or on one or more of its dimmers
Grey: Offline
(Blank): Not configured
Yellow: Console is trying to find rack
If a rack number is flashing, at least one dimmer in that rack is load learning.
{CLEAR} Clears all logged faults, e.g., {CLEAR} [*] (command mode) or {CLEAR}
{CLEAR} (direct action). Confirmation is required.
{RE-SYNC} Re-synchronizes dimmer log to current rack status. E.g., {RE-SYNC} [*]
(command mode) or {RE-SYNC} {RE-SYNC} (direct action)
{LEARN LOAD} Used as part of command line as follows:
{LEARN LOAD} {RACK} [#] [#] [*] [*]