User`s guide

43
Compool/EasyTouch Pool and Spa Control System Upgrade Installation and Users Guide
Solar
To enable a solar heater and set the temperature start and run time settings:
Up/Down buttons: Select Ye s or No to enable solar (1/2). In order to display the
solar selection as a heat source in the main screen, select Yes .
Right button: Select the Heat Pump setting.
Up/Down buttons: Select Yes or No to enable solar as a heat pump. Heat Pump
Control instead of Solar: Select Yes if a heat pump is being used in place of a solar
heating system. If Solar is set to heat pump, Valve A is free for other circuits.
Right button: Select 2 of 4 (2/4) to access the solar temperature differential start up
and run settings.
Up/Down buttons:
Start: Set the temperature differential to start heating from 3° to 9°. For example, if
“Start” is set to 3°, this ensures that the temperature has to deviate by 3° at least to
the specified set point temperature (in the Heat menu, on page 25) before it switches
on. Once the solar comes on it will start converging as it is heating. This ensures that
it will not continually be switching on and off.
Run: Set the temperature differential to stop heating from 2° to 5°. This setting sets
how close to the target set point temperature to switch off solar heat.
Press the Menu button to save the settings and to return to the Settings menu
options. Press the button again to return to the main menu options or press again to
return to the main screen.
Settings Menu: Delays
Setup which functions (pool/spa, and valves) to assign the delay feature. Delays can be assigned to the
following equipment.
Heater Cool-Down Delay Cancel: Shuts Filter Pump off immediately.
2-Speed Filter Pump five-minute START on HIGH SPEED Delay Cancel: Shifts pump to low
speed.
Automatic Pool Cleaner START Delay: Starts Cleaner Pump immediately, without normal delay in
which the filter pump first runs for 5 minutes.
Automatic Pool Cleaner SOLAR Delay: Allows Cleaner Pump to run even though solar delay has
shut it off for 5 minutes.
Some heaters require a cooldown cycle before being switched off. This can be setup to run the filter pump an
additional ten minutes to dissipate residual heat built up inside the heater combustion chamber. You can also
cancel the delay feature. For information about using the cancel delay feature, refer to “Delay Cancel” on
page 26.
Delays
To assign the delay feature:
Press the Up/Down buttons to select Ye s or No to enable or disable delays for the
pool and spa circuits (“Cooldown”). Press the Right button to select the valves
setting. Press the Down buttons to select Yes or No to enable or disable delays for
valves. Press the Menu button to save and to return to the Settings menu options.
Press the Menu button again to return to the main menu or press again to go to the
main screen.
Delays
Cooldown: No
Valves: No
MENU SETTINGS DELAYS DELAYS
Getting There
Solar 1/2
Enable: Yes
Heat Pump: No
Solar 2/2
Start: 6°
Run : 4°