User`s guide
34
Compool/EasyTouch Pool and Spa Control System Upgrade Installation and User’s Guide
Clean Filter PSI (1 - 50 psi) Default 14 PSI
The average PSI setting is between 10 PSI and 20 PSI for most pools and filters. The entered PSI
value splits the percentage meter for the filter. When the ""clean filter"" value is reached, EasyTouch
displays an alert message and the pump stops monitoring flow rates and starts managing pressure.
The value represents the change in pressure over time from start up (system clean) to present day
(system getting dirty). The changes can come from anywhere in the system, for example clogged
skimmers or pots in pumps. Setting this parameter at a lower level will cause the alert message to
come up sooner and you will have to clean your filter (cartridge) or backwash your filter (sand or DE)
sooner.
Backwash Flow GPM (15 - 130 GPM) Default 60 GPM.
Backwash Duration (1-60 minutes) Default 5 minutes.
Rinse Time (1-60 minutes) Default 1 minute.
Vacuum Flow GPM (15-130 GPM) Default 50 GPM
This setting sets the GPM that the pool vacuum will use.
Vacuum Time Mins. (1 - 600 minutes (10 hours) Default 10 minutes
This parameter can be set from 1 to 600 minutes. The typical setting is 10 minutes. This setting sets
the amount of time you wish to run the pool vacuum.
Status screen: Displays current operating information: GPM, RPM, Filter minutes, and pump
communication status.
Backwash
Clean Filt : 10
Flow GPM : 60
Duration : 5
Pump Vacuum
Flow (gpm) : 50
Time (min) : 10
IntelliFlo VF parameters (Continued)
GPM: 73
1927 RPM 1980 W
Filter: 7
Status: NORMAL