Operating instructions

34
Compool Cp3800
Auto
Control Panel and Spa-side Remote are enabled. Power Center keys are disabled.
Service
Power Center keys are enabled. Control Panel and Spa-side Remote are
disabled.
A blinking “Auto” status lamp indicates that the equipment is undergoing a 3-Hour program
override. See 3-hour Filter Override for details.
Caution
Manual-activation of equipment from the Power Center, will override any of the built-
in equipment interlocks and safety delay circuits.
The S key toggles the Intake and Return Valve Actuators through the
following options.
Spa circulation.
Fill spa.
Drain spa.
No status lamp indicates valves are in pool circulation.
The P key turns on the
Filter Pump.
Keys 1-7 activate auxiliary
equipment.
Activates the Heater and Solar.
3 - Hour Filter Override
It is possible to override the daily equipment operating cycles, and manually activate (or
deactivate) the filter pump and any of the 7 auxiliary circuits for a 3-Hour period. This is
particularly useful when adding chemicals to the pool.
Note
The Control System must be in “Auto” mode to enable these feature.
To turn the filter pump on, press the P key (Filter Pump) 2 times quickly. The “Auto” mode
Status Lamp will begin to blink, and the Filter Pump Status Lamp will illuminate for the 3-Hour
cycle.
To turn the filter pump off, press the P key (Filter Pump) 3 times quickly. The “Auto” mode
Status Lamp will begin to blink, and the Filter Pump Status Lamp will not be illuminated during
the 3-Hour cycle.
Sensor Status
If there is a fault with a temperature sensor, the appropriate status lamp will turn on. Check
cable and connections to appropriate sensor. If necessary, replace Temperature Sensor.