Operating instructions

parameters should be entered as decimal values,
representing a temperature in degrees Fahrenheit.
Please note that, for each target, the "High_Temp+1"
value should be entered as one unit higher than what
you will expect to see on the analog output of the
module (in other words, in the sample program, since
the desired high temp for the pool was 80 degrees F,
the correct parameter value to use was 81d).
CONTROL:
Spa_Toggle D Toggles power/control of Spa
Pool_Toggle D Toggles power/control of Pool
Aux(X)_Toggle D Toggles power to aux devices 1 - 7
Spa_Remote_Toggle D
Enable/disable remote control panel
located at Spa
Display_C/F_Toggle D
Toggles temperature display between
Celsius (C) & Fahrenheit (F); only affects
Cp3xxx display
Delay_Cancel D Disables circuit delays (not recommended)
Spa_Heat_(Off/On)_
Pool_Heat_(Off/On)
D Selects Off/On for spa and pool heater
Spa_Temp(X) D
Digits 0-9 for spa temperature keypad
(value in degrees F)
Spa_Temp_Clear D
'Clear' for spa temperature keypad; sets
value to "Spa_Low_Temp"
Spa_Temp_Up D
Raise temp on spa temperature keypad
(value in degrees F)
Spa_Temp_Down D
Lower temp on spa temperature keypad
(value in degrees F)
Spa_Temp_Enter D
'Enter' for spa temperature keypad (value
in degrees F)
Pool_Temp(X) D
Digits 0-9 for pool temperature keypad
(value in degrees F)
Pool_Temp_Clear D
'Clear' for pool temperature keypad; sets
value to "Pool_Low_Temp"
Pool_Temp_Up D
Raise temp on pool temperature keypad
(value in degrees F)
Pool_Temp_Down D
Lower temp on pool temperature keypad
(value in degrees F)
Pool_Temp_Enter D
'Enter' for pool temperature keypad (value
in degrees F)
Spa_Dimmer_Switch D Presses switch for spa dimmer control
Pool_Dimmer_Switch D Presses switch for pool dimmer control
Aux(X)
_Dimmer_Switch
D Presses switch for Aux(X) dimmer control
From_Device$ S
Routed from COM port for command
strings received from Compool
FEEDBACK:
Spa_On D Real feedback indicating spa circuit is on
Pool_On
D Real feedback indicating pool circuit is on
Aux(X)_On D
Real feedback indicating Aux(X) circuit is
on
Remotes_Enable D
When high/active, indicates spa side