Operating instructions
on the model of the Compool system:
Note that Aux4, 5, 6, and 7 are not available on the
3400.
Aux6 and 7 are not available on the 3600.
During normal operation, the "basic acknowledgement
packet" is transmitted to the Crestron controller
approximately every 2.5 seconds. This can be viewed as
a "keep alive" packet, or a system heartbeat. Every time
a "basic control packet" is sent from the Crestron
controller, it is answered immediately by an ACK packet
if received intact, or a NACK packet if it was not. This
module has been designed to resend the control data
packet if a NACK is received.
3x00/3830 3810 3820
Spa_Toggle Spa High Aux1
Pool_Toggle Pool Low Aux2
Aux1_Toggle Aux1 Aux1 Aux3
Aux2_Toggle Aux2 Aux2 Aux4
Aux3_Toggle Aux3 Aux3 Aux5
Aux4_Toggle Aux4 Aux4 Aux6
Aux5_Toggle Aux5 Aux5 Aux7
Aux6_Toggle Aux6 Aux6 Aux8
CRESTRON
HARDWARE
REQUIRED:
2-Series Processor
C2COM-3
CNMSX
CNXCOM
ST-COM
SETUP OF CRESTRON
HARDWARE:
Baud Rate - 9600
Parity - None
Data Bits - 8
Stop Bits - 1
RS-485 protocol
VENDOR FIRMWARE: Tested with version 2.7
VENDOR SETUP: The CP-3800 Control Panel should be connected to the
LX-3xxx Power Center using the 6-conductor wire
provided with the panel.
Correct time should be set using the "Hours" and
"Minutes" buttons on the CP-3800 panel.
Temperature sensors should be connected to the Power
Center, paying particular attention to the placement of
the green and red wires.
CABLE NUMBER: (none)
The pinout for the control cable is as follows:
" - Data" : Tie pins 1 & 9 on Crestron
-----> Pin 4 on RJ12 for Compool
" + Data" : Tie pins 4 & 6 on Crestron
-----> Pin 3 on RJ12 for Compool
GND : Pin 5 on Crestron
-----> Pin(s) 1 and/or 6 on RJ12 for Compool
PARAMETERS:
There are three parameters for the setting of the
desired pool temperature, and three parameters for the
setting of the desired spa temperature. These