(2k/3k) upper lead with a 300Ω/10W resistor to discharge +BUS capacitor
TO DISCHARGE the energy of charger capacitor, after disconnect the battery from
PSDR/Charger, you can use a 300Ω/10W resistor contact BAT (+) terminal and BAT (-)
terminal for discharge battery filter capacitor