Specifications

84 en | Terminal Screen Messages SCSI to SATA RAID Subsystem | Administrator’s Manual
F.01U.027.802 | V1 | 2006.11 Bosch Security Systems
6.4 Logical Drive Status
Fig. 6.4 Logical Drive Status Screen
i
NOTICE!
A logical drive in a single-controller subsystem is always managed by one controller, and the
“P” or “S” indicator will not appear.
LG Logical Drive number
LV The Logical volume to which this logical drive belongs
ID Controller-generated unique ID
RAID RAID level
SIZE (MB) Capacity of the Logical Drive
Status 1 Logical Drive Status – Column 1
GOOD The logical drive is in good condition
DRV FAILED A drive member failed in the logical drive
CREATING Logical drive is being initiated
DRV ABSENT An empty drive tray
INCOMPLETE Two or more drives failed in the logical drive
INVALID The logical drive was created but has not been fully initialized when
another version of firmware is being loaded. After the subsystem
resets, the array status should return to normal.
FATAL FAIL Two member drives failed at the same time, the array is inaccessible
DRV MISS A member drive is missing; could result from insecure installation
REBUILDING The logical drive is being rebuilt
Status 2 Logical Drive Status – Column 2
I Initializing drives
A Adding drive(s)
E Expanding logical drive
H Add drive operation on hold
Status 3 Logical Drive Status – Column 3
R Rebuilding the logical drive
P Regenerating array parity