5.9.3 Assigning a Name to a Logical Drive
Press ENT for two seconds to enter the Main Menu. Press the up or down arrow keys to select
"View and Edit Logical Drives..," then press ENT.
Press the up or down arrow keys to select a logical drive, then press ENT.
Press the up or down arrow keys to select “Logical Drive Name," then press ENT.
Press the up or down arrow keys to change the character of the flashing cursor. Press ENT to
move the cursor to the next space. The maximum number of characters for a logical drive
name is 14.
5.9.4 Rebuilding a Logical Drive (Manual Rebuild)
If you want the controller to auto-detect a replacement drive, make sure you have the follow-
ing options set to enabled:
1. Periodic Drive Check Time
2. Periodic Auto-Detect Failure Drive Swap Check Time
These two configuration options can be found under “View and Edit Configuration Parame-
ters” -> “ Drive-Side Parameters”.
A manual rebuild takes place after you replace the failed drive with a new drive that is known
to be good.
Press ENT for two seconds to enter the Main Menu. Press the up or down arrow keys to select
"View and Edit Logical Drives..", then press ENT.
Use the up or down arrow keys to select the logical drive that has a failed member, then press
ENT.
Use the up or down arrow keys to select “Rebuild Logical Drive," then press ENT.
Press ENT for two seconds to start rebuilding the logical drive.